Summary for Test 2021-04-21-5-7
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
Award Date | 04/21/2020 |
Closeout Date | Not set |
Work Description | Panther Creek & Hunter Creek Bridges |
Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 04/21/2021 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/26/2021 |
Sample type | Department Acceptance | A brief description of the sample | 1inch F1554 Gr36 Anchor Rod |
The quantity of what the sample constitutes | 64 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9165170532 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Thompson Metal Fab | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-055-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 1202027710 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Gr 36 | |
Bolt Length(s) | Nut Specification | N/A | |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 1 | Bolt Mfg. Lot Number | 120202771061 |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
Test Details
DIME Sample ID: 2021-04-21-5
DIME Test ID: 2021-04-21-5-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-04-28
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 04/27/2021
Sample No.: 1C
Rocap Number: no data
Heat Number(s): 1202027710
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: BLUE PAINT
Size: 1 in
Bolt Length: 43 in
Measurement Average: 5.43 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/28/2021 ✔