Summary for Test 2021-04-12-7-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 213653
DEA: 044G8204
EFIS: 0413000049
DIST-CO-RTE-PM04-MRN-101-10.6/10.8
Award Date05/05/2020
Closeout Date08/14/2023
Work DescriptionREPLACE SAN RAFAEL HARBOR BRIDGE (ABC)
Location DescriptionMARIN COUTY, IN SAN RAFAEL, FROM ROUTE 101 NORTHBOUND OFF-RAMP TO 2ND STREET
QA Service Level1 (Verified on 05/31/2019)

Sample Information

Sample Taken Date04/12/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/15/2021
Sample typeQuality Assurance A brief description of the sampleUltimate Welded Rebar Hoop
The quantity of what the sample constitutes150 From where was the sample collectedManufacturer
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-111-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)091221
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-3.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2021-04-12-7
DIME Test ID: 2021-04-12-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-04-15

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/15/2021
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1216/19mm0.4444505.39101149Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample