Summary for Test 2021-03-11-13-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214885
DEA: 080K1234
EFIS: 0815000242
DIST-CO-RTE-PM08---
Award Date06/03/2020
Closeout Date04/08/2022
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date03/11/2021 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2021
Sample typeVerification A brief description of the sampleJMF 3/4" RHMA-G-SP 1.0% LSM
The quantity of what the sample constitutes2 Bags of Coldfeed Lime Treated Agg., 11 Bags of Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byBlue Diamond Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0187G-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Diamond-Victorville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0040, 91-36-0106
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number300072 LSM LC A detailed description of where the material sample was collectedBelt Cut at Blue Diamond Victorville Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-03-11-13
DIME Test ID: 2021-03-11-13-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-04-15

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Friday Ofoegbu
Date of test: 04/10/2021
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 96 %
Cumulative percent passing the 1/2 in. sieve: 83 %
Cumulative percent passing the 3/8 in. sieve: 69 %
Cumulative percent passing the #4 sieve: 30 %
Cumulative percent passing the #8 sieve: 20 %
Cumulative percent passing the #16 sieve: 15 %
Cumulative percent passing the #30 sieve: 10 %
Cumulative percent passing the #50 sieve: 6 %
Cumulative percent passing the #100 sieve: 3 %
Cumulative percent passing the #200 sieve: 2.5 %
General comments (publicly viewable) (Max 1000 characters): Combined Lime Treated Aggregate

Test was verified on 4/15/2021