Summary for Test 2021-02-16-37-3
Test performed: AASHTO T312-14Project Information
Project Identifiers | Project ID: 214515 DEA: 024F6004 EFIS: 0213000012 |
---|---|
DIST-CO-RTE-PM | 02-SIS,TRI-36,96,299-VAR |
Award Date | 01/14/2020 |
Closeout Date | 08/24/2022 |
Work Description | BRIDGE DECK REPAIR, POLYESTER OVERLAY AND RAIL REPLACEMENT. |
Location Description | SISKIYOU AND TRINITY COUNTIES AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 02/16/2021 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/16/2021 |
Sample type | Verification | A brief description of the sample | 1/2-inch Type A HMA (PG 64-28 M) |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78745 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Mercer-Fraser Company, Willow Creek Plant, Willow Creek, CA | Transportation Laboratory (TL) Number | 853474 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-02-16-37
DIME Test ID: 2021-02-16-37-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T312-14: Preparing and Determining the Density of Asphalt Mixture Specimens by Means of the Superpave Gyratory Compactor (Method of Compaction)
Test Release Date: 2021-04-05
Test Results
HMA Type: Type A HMA
Is this test used for JMF verification: Yes
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 02/17/2021
Start time of test (military time): 1725
Specimen identification: 2021705
Percent Binder Content: 4.3 %
Average diameter of the mold: 150 mm
Height of the extruded specimen (Hm): 112.4 mm
Height of the specimen after 8 gyrations: 125.6 mm
Height of the specimen after 85 gyrations: 113.7 mm
Height of the specimen after 130 gyrations: 112.4 mm
Mass of the specimen: 4999.8 g
Maximum Specific Gravity (Gmm): 2.642
Bulk Specific Gravity (Gmb): 2.593
Unit weight of water: 1 g/cm^3
Gyration Angle: 1.16 deg
Gyration Angle: 20.2 mrad
Method used to verify gyration angle: AASHTO T 344 at room temperature
Volume of the specimen (Vm8): 2218.410 cm^3
Volume of the specimen (Vm85): 2008.226 cm^3
Volume of the specimen (Vm130): 1985.265 cm^3
Uncorrected relative density (Gmmu8): 85.3 %
Uncorrected relative density (Gmmu85): 94.2 %
Uncorrected relative density (Gmmu130): 95.3 %
Relative density (Gmm8): 87.8 %
Relative density (Gmm85): 97.0 %
Relative density (Gmm130): 98.1 %
Air Voids (AV8): 12.2 %
Air Voids (AV85): 3.0 %
Air Voids (AV130): 1.9 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/5/2021 ✔