Summary for Test 2020-11-12-40-1
Test performed: AASHTO T11-5Project Information
Project Identifiers | Project ID: 213835 DEA: 051F7404 EFIS: 0514000049 |
---|---|
DIST-CO-RTE-PM | 05-MON-101-R28.0/R30.6 |
Award Date | 04/03/2019 |
Closeout Date | 08/23/2021 |
Work Description | PLACE CONTINUOUSLY REINFORCED CONCRETE PAVEMENT ON EXISTING ROADWAY. |
Location Description | MONTEREY COUNTY NEAR SAN LUCAS FROM 0.1 MILE SOUTH OF PARIS VALLEY ROAD OVERCROSSING TO RANCHO UNDERCROSSING |
QA Service Level | 1 (Verified on 02/18/2019) |
Sample Information
Sample Taken Date | 11/12/2020 | Sample Unique Key | 40 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/29/2021 |
Sample type | Dispute Resolution | A brief description of the sample | 3/4 HMA L1, SL1 |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Job Site |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | Wood |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 21-HMA-0046 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | SPM Avenal | Transportation Laboratory (TL) Number | C979428 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | na |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Production Paving | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | 1 | |
Sublot number | 1 | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-11-12-40
DIME Test ID: 2020-11-12-40-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Test Release Date: 2021-04-01
Test Results
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 03/30/2021
Which test procedure is being used: Method A
Mass of test sample (before test): 628.5 grams
Mass of test sample (after test): 565.8 grams
Percent of sample passing the #200 sieve (by mass): 10 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/1/2021 ✔