Summary for Test 2015-06-26-7-1

Test performed: CTM 521-November 2014

Project Information

Project IdentifiersProject ID: 5266
DEA: 08448404
EFIS: 0800000712
COOP: 081488A1
DIST-CO-RTE-PM08-RIV-91-15.6/21.6
Award Date02/10/2012
Closeout Date07/27/2023
Work DescriptionCONSTRUCT HOV LANES AND WIDEN BRIDGES.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM ADAMS STREET TO THE ROUTE 60/215 SEPARATION
QA Service Level1 (Verified on 04/27/2012)

Sample Information

Sample Taken Date06/26/2015 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/30/2015
Sample typeQuality Control A brief description of the sample6x12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byEDWIN Last name of sampler or witnessed byEDLES
Title of samplerTE Telephone number of samplerUnknown
Laboratory sample identification825-26 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameJOB Transportation Laboratory (TL) Number015629
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierSR 91 MADISON AVE to UNIVERSITY AVE IN RIV
Structure nameDS 108 i MANHOLE EZ AT VINE ST

Material Information

Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collected2E 07
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedCHUTE Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-06-26-7
DIME Test ID: 2015-06-26-7-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-07-01

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/01/2015
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 69980 lb
Maximum load on cylinder 2: 66260 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 5 days
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 2483.3 psi
Compressive strength of cylinder 2: 2351.3 psi
Compressive strength (to nearest 10 psi): 2420 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/1/2015