Summary for Test 2020-12-03-14-1

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 212657
DEA: 024G5004
EFIS: 0214000031
DIST-CO-RTE-PM02-TRI-299-1.9-2.3
Award Date10/01/2019
Closeout Date11/24/2021
Work DescriptionVIADUCT WIDENING
Location DescriptionTRINITY COUNTY NEAR SALYER FROM 0.1 MILE EAST TO 0.6 MILE EAST OF WHITE HOUSE GULCH ROAD
QA Service Level1 (Verified on 09/04/2018)

Sample Information

Sample Taken Date12/03/2020 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/03/2020
Sample typePer Request A brief description of the sampleFine PCC Aggregate
The quantity of what the sample constitutesUnknown Quantity From where was the sample collectedManufacturer
First name of sampler or witnessed byColt Last name of sampler or witnessed bySweeny
Title of sampler Telephone number of sampler
Laboratory sample identificationD78703B Linked DIME Sample ID
The fabricator/manufacturer/facility nameEureka Ready Mix Transportation Laboratory (TL) Number897722
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unkown
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-12-03-14
DIME Test ID: 2020-12-03-14-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2021-03-24

Test Results


What size aggregate is being tested?: Fine Aggregate
Input Type: Calculated
Tester's full name: BN/JH
Date of test: 03/24/2021
Percentage Loss of material retained on #8 sieve: no data
Percentage Loss of material retained on #16 sieve: no data
Percentage Loss of material retained on #30 sieve: no data
Percentage Loss of material retained on #50 sieve: no data
Percentage Loss of material retained on #100 sieve: no data
Weighted Average Percent Loss of Fine Aggregate: 5.0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/24/2021