Summary for Test 2021-03-15-1-3

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 214176
DEA: 033F0904
EFIS: 0312000056
DIST-CO-RTE-PM03-SAC,SJ-5,160-Var
Award Date10/10/2019
Closeout Date10/27/2022
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGES, PLACE CIDH & CISS CONCRETE PILES.
Location DescriptionSACRAMENTO COUNTY AT NORTH SACRAMENTO UNDERCROSSING AND SACRAMENTO RIVER BRIDGE AND IN SAN JOAQUIN COUNTY AT MOKELUMNE RIVER BRIDGE
QA Service Level1 (Verified on 05/29/2019)

Sample Information

Sample Taken Date03/15/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/17/2021
Sample typeQuality Assurance A brief description of the sample#8 Dextra Bartech End Anchors
The quantity of what the sample constitutes20 assemblies From where was the sample collectedFabricator
First name of sampler or witnessed byJane Last name of sampler or witnessed byLillard
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler9162918042
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCamblin Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS52-009-21 lot 3 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4102040 Head Manufacturer Lot Number(s)5076
Rebar Size#8 Headed Bar Model Name8 Bartech End Anchor
Size of HeadFull Size - 9x Head Connection TypeThreaded
Head ShapeCircular Rebar ManufacturerCMC Arizona
Head ManufacturerDextra America Head FabricatorDextra America
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2021-03-15-1
DIME Test ID: 2021-03-15-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-03-18

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 03/18/2021
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
110.797687397307Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 3/18/2021