Summary for Test 2021-03-01-11-5
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 213653 DEA: 044G8204 EFIS: 0413000049 |
---|---|
DIST-CO-RTE-PM | 04-MRN-101-10.6/10.8 |
Award Date | 05/05/2020 |
Closeout Date | 08/14/2023 |
Work Description | REPLACE SAN RAFAEL HARBOR BRIDGE (ABC) |
Location Description | MARIN COUTY, IN SAN RAFAEL, FROM ROUTE 101 NORTHBOUND OFF-RAMP TO 2ND STREET |
QA Service Level | 1 (Verified on 05/31/2019) |
Sample Information
Sample Taken Date | 03/01/2021 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/11/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1” x 5-1/2” bolt with washer and nut |
The quantity of what the sample constitutes | 15 assemblies | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Eure |
Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 843-509-1283 |
Laboratory sample identification | AB547AS | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Acrow Bridge | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B-385-001-21 | Structure unique identifier | |
Structure name | Temporary Modular Bridge |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TBD |
---|---|---|---|
Heat Number(s) | TBD | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | ASTM F3125 Grade A325 | |
Bolt Length(s) | 5-1/2” | Nut Specification | ASTM A563 Grade DH |
Washer Specification | ASTM F436 | Finish | HDG ASTM A153 |
Diameter/Size | 1" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-03-01-11
DIME Test ID: 2021-03-01-11-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-03-25
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 03/17/2021
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: AB547AS
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: no data
Size: 1 in
Bolt Length: 5.50 in
Measurement Average: 4.45 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/25/2021 ✔