Summary for Test 2021-02-01-29-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/01/2021 | Sample Unique Key | 29 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/10/2021 |
Sample type | Verification | A brief description of the sample | Asphalt Binder |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Valorie | Last name of sampler or witnessed by | Rice |
Title of sampler | COC Program | Telephone number of sampler | |
Laboratory sample identification | 5834M-0171 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Valero Benicia | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | 507 | |
Time of sample | 0600 | HMA Supplier | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-02-01-29
DIME Test ID: 2021-02-01-29-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-03-19
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 03/17/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 174.382 grams
Mass of empty container #2: 174.370 grams
Mass of container #1 before test (m1i): 210.245 grams
Mass of container #2 before test (m2i): 210.126 grams
Mass of container #1 after test (m1f): 210.001 grams
Mass of container #2 after test (m2f): 209.867 grams
Average mass change: -0.702 percent
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs
Test was verified on 3/19/2021 ✔