Summary for Test 2021-01-10-4-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/10/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/08/2021
Sample typeVerification A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes1 of 3 cans From where was the sample collectedManufacturer
First name of sampler or witnessed byERIC Last name of sampler or witnessed byGauss
Title of samplerCOC Program Telephone number of sampler
Laboratory sample identification011021-751 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVALERO - WILMINGTON Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-16
ModifiedNo Lot number
Sublot number Tank number8
Time of sample08:00 HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Wilmington CA MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-01-10-4
DIME Test ID: 2021-01-10-4-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-03-19

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 03/17/2021
Ductility of test #1 (D1): 110 cm
Ductility of test #2 (D2): 123 cm
Ductility of sample: 117 cm
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs

Test was verified on 3/19/2021