Summary for Test 2021-02-19-5-4

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212085
DEA: 07296604
EFIS: 0713000057
DIST-CO-RTE-PM07-LA-10-14.0/19.0
Award Date06/04/2018
Closeout Date05/04/2023
Work DescriptionPAINT AND REHABILITATE BRIDGE - (STRAIN (PAINT AND INSTALL CATWALK)
Location DescriptionIN THE CITY OF LOS ANGELES, AT SANTA MONICA VIADUCT (BR. NO. 53-1301). PAINT AND REHABILITATE BRIDGE
QA Service Level1 (Verified on 07/25/2018)

Sample Information

Sample Taken Date02/19/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/19/2021
Sample typeVerification A brief description of the sampleA325 Fastener Assembly
The quantity of what the sample constitutes1448 From where was the sample collectedDistributor
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePage Industrial Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-048-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)33546-201422
Washer Mfg. Lot Number(s)D9458 Bolt SpecificationASTM A325TC
Bolt Length(s)2 1/4" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishMechanical Galvanized
Diameter/Size3/4" Bolt Mfg. Lot Number33532-10669080
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2021-02-19-5
DIME Test ID: 2021-02-19-5-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-03-16

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 03/12/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B33546-20142252937fsaylor

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 3/16/2021