Summary for Test 2020-10-29-21-3
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 215563 Permit Numbers: 10196MC0162 |
---|---|
DIST-CO-RTE-PM | 10---30.828 |
Award Date | 03/05/2019 |
Closeout Date | Not set |
Work Description | To widen Beckman Road by adding a continuous left turn lane. |
Location Description | SR 99, Lodi |
QA Service Level | 2 (Verified on 05/10/2023) |
Sample Information
Sample Taken Date | 10/29/2020 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/09/2021 |
Sample type | Acceptance | A brief description of the sample | Asphalt Binder Sample |
The quantity of what the sample constitutes | 1-1 | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Pacific Northwest Oil | Transportation Laboratory (TL) Number | 034781 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | Knife River Vernalis | |
Certified Asphalt Supplier | Pacific Northwest Oil - Stockton CA | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-29-21
DIME Test ID: 2020-10-29-21-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-03-12
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 03/11/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.156 kPa
Phase Angle (δ) (for the 10 cycles): 87.5 degree
Complex Modulus (G*) (for the 10 measurements): 1.298 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.30 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Std Specs ORIG
Test was verified on 3/12/2021 ✔