Summary for Test 2020-08-10-47-6
Test performed: AASHTO T324-14Project Information
Project Identifiers | Project ID: 214618 DEA: 033F99U4 EFIS: 0319000311 |
---|---|
DIST-CO-RTE-PM | 03-SUT-99-39.2/41.4 |
Award Date | 05/15/2020 |
Closeout Date | 12/13/2023 |
Work Description | WIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM. |
Location Description | SUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION) |
QA Service Level | 1 (Verified on 03/24/2020) |
Sample Information
Sample Taken Date | 08/10/2020 | Sample Unique Key | 47 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/11/2021 |
Sample type | Verification | A brief description of the sample | 3/4 inch RHMA-G |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brad | Last name of sampler or witnessed by | Mckeehan (WITNESS) |
Title of sampler | DGS Personnel | Telephone number of sampler | |
Laboratory sample identification | JMF20-030B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | DSG Aggregates - Marysville | Transportation Laboratory (TL) Number | C 779832 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-08-10-47
DIME Test ID: 2020-08-10-47-6
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-02-25
Test Results
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 08/25/2020
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 4.67 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 4.57 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
General comments (publicly viewable) (Max 1000 characters): JMF20-030B.
Test was verified on 2/25/2021 ✔