Summary for Test 2021-02-11-4-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214922 DEA: 100X3104 EFIS: 1013000265 |
---|---|
DIST-CO-RTE-PM | 10-SJ-99-16.8/17.6 |
Award Date | 06/30/2020 |
Closeout Date | 04/07/2022 |
Work Description | REPLACE BRIDGE. |
Location Description | SAN JOAQUIN COUNTY IN STOCKTON FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF FARMINGTON ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 04/28/2020) |
Sample Information
Sample Taken Date | 02/11/2021 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/12/2021 |
Sample type | Quality Assurance | A brief description of the sample | Double Barrel Zap Screwlok |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | A | Last name of sampler or witnessed by | jox |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar Barsplice | Transportation Laboratory (TL) Number | C923930 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC Rebar |
Coupler Manufacturer | Barsplice | Intermediate Assembler or Fabricator | |
Rebar Size | #4 | Coupler Model | Double Barrel Zap Screwlok |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | 9085 | Rebar Heat Number(s) | 4103926 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2021-02-11-4
DIME Test ID: 2021-02-11-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-02-16
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 02/16/2021
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | 4/13mm | 0.2 | 19109.86 | 95549 | Service Splice | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 2/16/2021 ✔