Summary for Test 2020-07-22-57-2
Test performed: AASHTO T275-07r12Project Information
Project Identifiers | Project ID: 214802 DEA: 031G7004 EFIS: 0319000135 |
---|---|
DIST-CO-RTE-PM | 03-SUT-99-28.0/30.6 |
Award Date | 05/18/2020 |
Closeout Date | 03/16/2021 |
Work Description | COLD PLANE AC PAVEMENT, RHMA OVERLAY, & INDUCTIVE LOOP DETECTORS. |
Location Description | SUTTER COUNTY IN AND NEAR YUBA CITY FROM 0.1 MILE NORTH OF SMITH ROAD TO ROUTE 20 |
QA Service Level | 1 (Verified on 03/24/2020) |
Sample Information
Sample Taken Date | 07/22/2020 | Sample Unique Key | 57 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2020 |
Sample type | Verification | A brief description of the sample | 3/4" RHMA-G |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | DSG Personnel | Last name of sampler or witnessed by | DSG Personnel |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | JMF20-030 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | DeSilva Gates Aggregates-Marysville | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-07-22-57
DIME Test ID: 2020-07-22-57-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2021-02-09
Test Results
Number of tests: 3
What test procedure is performed?: Method A
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 07/23/2020
Bulk Specific Gravity: 2.600
Bulk Specific Gravity 2: 2.800
Bulk Specific Gravity 3: 3.100
Average Bulk Specific Gravity: 2.8
General comments (publicly viewable) (Max 1000 characters): JMF20-030. Test date estimated.
Test was verified on 2/9/2021 ✔