Summary for Test 2021-01-25-2-3
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/25/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/26/2021 |
Sample type | Verification | A brief description of the sample | 3/4 Type A HMA, PG64-16. w/ RAP |
The quantity of what the sample constitutes | 20 boxes | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Ignocencio | Last name of sampler or witnessed by | Herrera |
Title of sampler | TE | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Syar Industries | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-01-25-2
DIME Test ID: 2021-01-25-2-3
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-02-04
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Frank Chavez Jr
Date of test: 01/26/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2032.0 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1879.4 g
Correction Factor (Percent by mass of HMA Specimen): 2.09 %
Moisture Content: 0.17 %
Temperature Compensation Factor: no data
Test Temperature: 482 F
Corrected Asphalt Binder Content: 5.25 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/4/2021 ✔