Summary for Test 2020-12-29-3-10
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/29/2020 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/29/2020 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed 1.0" Crushed PCC Aggregate |
The quantity of what the sample constitutes | 8 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Maldonado |
Title of sampler | Quality Control Tech | Telephone number of sampler | |
Laboratory sample identification | 2928 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | VULCAN FISH CANYON QUARRY | Transportation Laboratory (TL) Number | C-2020-11-12-21 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA or name of Pit) | 91-19-0035::FISH CANYON QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stckpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-12-29-3
DIME Test ID: 2020-12-29-3-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2021-02-02
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 01/11/2021
Top sediment column reading (single primary size): 0.3 in
Cleanness value (single primary size): 91
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/2/2021 ✔