Summary for Test 2021-01-28-4-5

Test performed: AASHTO T324-14
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/28/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/28/2021
Sample typeQuality Control A brief description of the sample1/2 HMA Type A
The quantity of what the sample constitutesJMF Renewal From where was the sample collectedSupplier
First name of sampler or witnessed byTBD Last name of sampler or witnessed byTBD
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Felton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2021-01-28-4
DIME Test ID: 2021-01-28-4-5
Testing Lab: Granite Construction Company - Coastal
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-01-29

Test Results


Input Type: Calculated
Tester's full name: Gwynn Neilson
Date of test: 03/26/2019
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 10000
Impression at specified number of passes average: 14651 mm
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 20000 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 20000 mm
Stripping Inflection Point (Wheel A): 13897
Stripping Inflection Point (Wheel B): 15405
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/29/2021

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.