Summary for Test 2021-01-07-5-2

Test performed: ASTM D638-Dec14

Project Information

Project IdentifiersProject ID: 214908
DEA: 112N0424
EFIS: 1118000193
DIST-CO-RTE-PM11-SD-76-R4.2/R6.4
Award Date06/09/2020
Closeout Date01/31/2022
Work DescriptionPLACE MICROSURFACING, COLD PLANE AND REPLACE AC WITH HOT MIX ASPHALT.
Location DescriptionSAN DIEGO COUNTY IN OCEANSIDE FROM RANCHO DEL ORO DRIVE TO 0.2 MILE EAST OF COLLEGE BOULEVARD
QA Service Level1 (Verified on 09/15/2020)

Sample Information

Sample Taken Date01/07/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/15/2021
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byTikusis
Title of samplerTechnical Director Telephone number of sampler707-330-9227
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers and Polynt Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypePolyester Mfg. Lot Number(s)1301717
Batch number1301717 Mix number1301717

Test Details

DIME Sample ID: 2021-01-07-5
DIME Test ID: 2021-01-07-5-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Test Release Date: 2021-01-28

Test Results


Number of specimens tested: 5
Input Type: Calculated
Tester's full name: Phillip Montes
Date of test: 01/27/2021
Conditioning procedure: 40/25/50
Speed of testing: 0.2 in/min
Sample 1 Width: 0.497 in
Sample 1 Thickness: 0.132 in
Sample 1 Area: 0.0656 in^2
Sample 1 Ultimate Strength Actual: 203 lbs
Sample 1 percent elongation: 32.3 %
Sample 1 Time: 6 MM:SS
Sample 2 Width: 0.495 in
Sample 2 Thickness: 0.119 in
Sample 2 Area: 0.0589 in^2
Sample 2 Ultimate Strength Actual: 188.7 lbs
Sample 2 percent elongation: 37 %
Sample 2 Time: 7 MM:SS
Sample 3 Width: 0.488 in
Sample 3 Thickness: 0.121 in
Sample 3 Area: 0.059 in^2
Sample 3 Ultimate Strength Actual: 186 lbs
Sample 3 percent elongation: 38.4 %
Sample 3 Time: 6 MM:SS
Sample 4 Width: 0.491 in
Sample 4 Thickness: 0.116 in
Sample 4 Area: 0.057 in^2
Sample 4 Ultimate Strength Actual: 193.4 lbs
Sample 4 percent elongation: 38.7 %
Sample 4 Time: 7 MM:SS
Sample 5 Width: 0.494 in
Sample 5 Thickness: 0.12 in
Sample 5 Area: 0.0593 in^2
Sample 5 Ultimate Strength Actual: 193.7 lbs
Sample 5 percent elongation: 37.7 %
Sample 5 Time: 6 MM:SS
Sample 1 Ultimate strength: 3095 psi
Sample 2 Ultimate strength : 3204 psi
Sample 3 Ultimate strength: 3153 psi
Sample 4 Ultimate strength: 3393 psi
Sample 5 Ultimate strength: 3266 psi
Ultimate Strength Average: 3222.2 psi
Percent Elongation Average: 36.82 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/28/2021