Test 2020-12-15-20-2 (AASHTO T51-13) Summary

Project Information
Project IdentifiersProject ID: 215023
DEA: 060U4704
EFIS: 0615000301
DIST-CO-RTE-PM06-KER,KIN-5-81.7/87.0,0.0/0.3
Work DescriptionCONSTRUCT CRCP, JPCP AND INSTALL TRAFFIC MONITORING STATIONS.
Location DescriptionKERN AND KINGS COUNTIES NEAR KETTELMAN CITY FROM 0.6 MILE SOUTH OF TWISSELMAN ROAD OVERCROSSING TO 0.3 MILE NORTH OF KERN/KINGS COUNTY LINE
Sample Information
Sample Taken Date12/15/2020 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/22/2021
Sample typeAcceptance A brief description of the sampleProject Sample
The quantity of what the sample constitutes1 of 1 From where was the sample collectedSource
First name of sampler or witnessed byG. Last name of sampler or witnessed byDILT
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameSPM AVENAL Transportation Laboratory (TL) NumberC040288
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA SupplierNot set
Asphalt Binder SupplierNot set MultigradeNot set
Multigrade TypeNot set HMA Design ID
Test Details
DIME Sample ID: 2020-12-15-20
DIME Test ID: 2020-12-15-20-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-01-27
Test Results

Is a normal test obtainable?: Yes
Number of replicates tested: Three
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 01/26/2021
Ductility of test #1 (D1): 110 cm
Ductility of test #2 (D2): 150 cm
Ductility of test #3 (D3): 150 cm
Ductility of sample:137 cm
General comments (publicly viewable) (Max 1000 characters): per 2018 specifications standards

Test was verified on 01/27/2021