Summary for Test 2019-05-13-17-7
Test performed: AASHTO T324-14Project Information
Project Identifiers | Project ID: 214175 DEA: 030H4804 EFIS: 0315000198 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-0.1/1.6,11.8/21.6 |
Award Date | 08/20/2019 |
Closeout Date | 08/11/2023 |
Work Description | COLD PLANE AC PAVEMENT AND RHMA OVERLAY. |
Location Description | SACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD |
QA Service Level | 1 (Verified on 05/29/2019) |
Sample Information
Sample Taken Date | 05/13/2019 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2020 |
Sample type | Verification | A brief description of the sample | 3/4" HMA - A |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | J. | Last name of sampler or witnessed by | Kort (WITNESS) |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | JMF20-013 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | George Reed - Clements Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-05-13-17
DIME Test ID: 2019-05-13-17-7
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-01-21
Test Results
Input Type: Calculated
Tester's full name: D-10 Lab Personnel
Date of test: 05/24/2019
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 0
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 0
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 3.05 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 2.97 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
General comments (publicly viewable) (Max 1000 characters): Data submitted for administrative purposes; lab tests were performed by D-10 Lab personnel. Test date is an estimated guess, based on a completed CEM-3513 form from D-10.
Test was verified on 1/21/2021 ✔