Summary for Test 2020-12-30-9-23

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 214702
DEA: 030F2864
EFIS: 0320000123
DIST-CO-RTE-PM03-SAC-99-7.92 / 8.4
Award Date06/24/2020
Closeout Date11/28/2023
Work DescriptionRemove and replace Consumnes River and Consumnes River Overflow bridge
Location DescriptionSacramento County
QA Service Level1 (Verified on 04/20/2020)

Sample Information

Sample Taken Date12/30/2020 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/07/2021
Sample typeQuality Assurance A brief description of the sample.6in Prestressing Strand
The quantity of what the sample constitutes61 From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byHiranaga
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s) Number of Coils
Group Number10961 Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0569320-2, S0569120-2, S0569720-3, S0514120-2, S0525620, S0568320, S0218590, S0216056, S0218045, S0559420-2, S0514420-2, S0513920-2, S0514320-2 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2020-12-30-9
DIME Test ID: 2020-12-30-9-23
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-01-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 01/08/2021
UTM: 120kip
Temperature: 72 f
Extensometers: no data
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0514320-2S379481-60.2185992257399.928.61.77bewing

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 1/12/2021