Summary for Test 2020-11-19-7-8
Test performed: AASHTO T301-13Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/19/2020 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/29/2020 |
Sample type | Verification | A brief description of the sample | COC Sample |
The quantity of what the sample constitutes | 1 of 2 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | NOT | Last name of sampler or witnessed by | PROVIDED |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 20642829 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | San Joaquin Refining Co Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | 5005 | |
Time of sample | HMA Supplier | Not set | |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-11-19-7
DIME Test ID: 2020-11-19-7-8
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T301-13: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Test Release Date: 2021-01-06
Test Results
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 01/04/2021
Final Reading from the testing machine (X): 3 cm
% Elongation Recovery: 85 %
General comments (publicly viewable) (Max 1000 characters): PER 2018 STANDARD SPECIFICATIONS
Test was verified on 1/6/2021 ✔