Summary for Test 2020-10-29-15-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 212657 DEA: 024G5004 EFIS: 0214000031 |
---|---|
DIST-CO-RTE-PM | 02-TRI-299-1.9-2.3 |
Award Date | 10/01/2019 |
Closeout Date | 11/24/2021 |
Work Description | VIADUCT WIDENING |
Location Description | TRINITY COUNTY NEAR SALYER FROM 0.1 MILE EAST TO 0.6 MILE EAST OF WHITE HOUSE GULCH ROAD |
QA Service Level | 1 (Verified on 09/04/2018) |
Sample Information
Sample Taken Date | 10/29/2020 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/14/2020 |
Sample type | Quality Assurance | A brief description of the sample | ASPHALT BINDER |
The quantity of what the sample constitutes | 1 of 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | C | Last name of sampler or witnessed by | BRYANT |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | MERCERFRASER WILLOWCREEK | Transportation Laboratory (TL) Number | C85339 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | Not set | |
Time of sample | Not set | HMA Supplier | Not set |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-29-15
DIME Test ID: 2020-10-29-15-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2020-12-30
Test Results
Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 12/23/2020
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 167.460 grams
Mass of container #1 before test (m1i): 203.904 grams
Mass of container #1 after test (m1f): 203.769 grams
Average mass change: -0.370 percent
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs
Test was verified on 12/30/2020 ✔