Summary for Test 2020-12-01-15-1

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 215374
DEA: 060X2704
EFIS: 0618000048
DIST-CO-RTE-PM06-FRE-5-37.2/48.8
Award DateNot set
Closeout DateNot set
Work DescriptionPAVEMENT REHABILITATION
Location DescriptionFROM 1.9 MILES NORTH OF THREE ROCKS ROAD UC TO 0.2 MILES SOUTH OF PANOCHE ROAD OC
QA Service Level1 (Verified on 12/16/2020)

Sample Information

Sample Taken Date12/01/2020 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/15/2020
Sample typePer Request A brief description of the samplesoil
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byE Last name of sampler or witnessed byEasterling
Title of samplerTransportation Engineer Telephone number of sampler
Laboratory sample identificationCR20200561 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) NumberC0X2702
Inspector Lot Number from the Transportation Laboratory (TL) Form12/2/2020 Structure unique identifier06-FRE-5-PM 37.2/48.8
Structure nameEast Side of I-5 at PM 43

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample20-D-084
The fabricator/manufacturer designation for the samplecorrosion testing A detailed description of where the material sample was collectedEast side of I-5 at PM 43.73, at surface at Outlet
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2020-12-01-15
DIME Test ID: 2020-12-01-15-1
Testing Lab: Wood
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-12-23

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Tim Steele
Date of test: 12/22/2020
Minimum soil resistance of the lab measurement: 740 Ohms
Soil sample temperature: 18 C
Soil box constant: 1
pH of soil: 6.83
Minimum soil resistance corrected to 15.5: 786.00 Ohm-cm
Minimum soil resistivity at 15.5: 786 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/23/2020