Summary for Test 2020-12-04-12-3

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date12/04/2020 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/04/2020
Sample typePreliminary A brief description of the sample1/2" HMA-SP WMA
The quantity of what the sample constitutes780 Pounds From where was the sample collectedManufacturer
First name of sampler or witnessed byCody Last name of sampler or witnessed byBrown
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID311100010-TB_1220
The fabricator/manufacturer/facility nameSyar Indunsties Todd Rd Batch Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-12-04-12
DIME Test ID: 2020-12-04-12-3
Testing Lab: Syar Industries, Incorporated
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2020-12-16

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Cody Brown
Date of test: 12/04/2020
Specimen Treatment: Untreated
Average Dry Tensile Strength: 104 psi
Average Wet Tensile Strength: 80 psi
Tensile Strength Ratio: 76.92
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/16/2020