Summary for Test 2020-10-15-22-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 215312 DEA: 034H5800 EFIS: 0318000336 |
---|---|
DIST-CO-RTE-PM | 03-SAC-5-22.5/34.3 |
Award Date | 01/14/2025 |
Closeout Date | Not set |
Work Description | I-5 Managed Lanes |
Location Description | Not set |
QA Service Level | 2 (Verified on 12/02/2020) |
Sample Information
Sample Taken Date | 10/15/2020 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/18/2020 |
Sample type | Per Request | A brief description of the sample | native soil |
The quantity of what the sample constitutes | bag of soil | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Joseph | Last name of sampler or witnessed by | Klamecki |
Title of sampler | Engineering Geologist | Telephone number of sampler | 916-447-7716 |
Laboratory sample identification | CR20200494 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | C021602 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 03-SAC-5-29.02 | |
Structure name | Del Paso Rd OC Retaining Wall and Abutment 1 |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Soil Pit HA-20-001 |
---|---|---|---|
The fabricator/manufacturer designation for the sample | corrosion | A detailed description of where the material sample was collected | Soil Pit on N side of Abutment 1 embankment 0-1 feet depth |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-10-15-22
DIME Test ID: 2020-10-15-22-1
Testing Lab: Wood
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-12-01
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Sarah Mauri
Date of test: 11/25/2020
Minimum soil resistance of the lab measurement: 1100 Ohms
Soil sample temperature: 22.1 C
Soil box constant: 1
pH of soil: 7.51
Minimum soil resistance corrected to 15.5: 1282.00 Ohm-cm
Minimum soil resistivity at 15.5: 1282 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/1/2020 ✔