Summary for Test 2020-10-14-38-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 215315 DEA: 081H8304 EFIS: 0817000139 |
---|---|
DIST-CO-RTE-PM | 08-SBD,SBD-138-0/2.3 |
Award Date | 11/19/2021 |
Closeout Date | Not set |
Work Description | CONSTRUCT 4' MEDIAN |
Location Description | SAN BERNARDINO COUNTY ALONG ROUTE 138 |
QA Service Level | 1 (Verified on 06/24/2021) |
Sample Information
Sample Taken Date | 10/14/2020 | Sample Unique Key | 38 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/18/2020 |
Sample type | Per Request | A brief description of the sample | soil |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kazi | Last name of sampler or witnessed by | Ahmed |
Title of sampler | unknown | Telephone number of sampler | 909-806-3964 |
Laboratory sample identification | CR20200517 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | C002254 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 08-SBD-138-PM-2.0 | |
Structure name | Southbound |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | A-20-005 |
---|---|---|---|
The fabricator/manufacturer designation for the sample | lab testing | A detailed description of where the material sample was collected | 5 feet |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-10-14-38
DIME Test ID: 2020-10-14-38-1
Testing Lab: Wood
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-11-24
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Sarah Mauri
Date of test: 11/23/2020
Minimum soil resistance of the lab measurement: 4500 Ohms
Soil sample temperature: 20.4 C
Soil box constant: 1
pH of soil: 8.37
Minimum soil resistance corrected to 15.5: 5051.00 Ohm-cm
Minimum soil resistivity at 15.5: 5051 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/24/2020 ✔