Test 2020-04-17-19-9 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 212914
DEA: 031E0604
EFIS: 0312000068
DIST-CO-RTE-PM03-YUB-70-15.5/16.5
Work DescriptionSIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055.
Location DescriptionNEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019.
Sample Information
Sample Taken Date4/17/2020 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/20/2020
Sample typeVerification A brief description of the sample3/4 inch RHMA-G
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byKenny witness not sampler Last name of sampler or witnessed byMcHugh witness not sampler
Title of samplerTeichert Personnel Laboratory sample identificationJMF20-018
The fabricator/manufacturer/facility nameTeichert Hallwood Transportation Laboratory (TL) NumberC741852
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-58-0006
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3513-2020-221
Test Details
DIME Sample ID: 2020-04-17-19
DIME Test ID: 2020-04-17-19-9
Testing Lab: CT D03 - North Region Materials Lab
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-11-23
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 04/21/2020
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:98 %
Cumulative percent passing the 1/2 in. sieve:90 %
Cumulative percent passing the 3/8 in. sieve:71 %
Cumulative percent passing the #4 sieve:33 %
Cumulative percent passing the #8 sieve:17 %
Cumulative percent passing the #16 sieve:11 %
Cumulative percent passing the #30 sieve:8 %
Cumulative percent passing the #50 sieve:5 %
Cumulative percent passing the #100 sieve:4 %
Cumulative percent passing the #200 sieve:2.5 %
General comments (publicly viewable) (Max 1000 characters): JMF20-018. Test date estimated.

Test was verified on 11/23/2020