Test 2020-10-05-31-1 (AASHTO T240-17) Summary

Project Information
Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date10/5/2020 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/13/2020
Sample typeVerification A brief description of the sampleAsphalt Binder PG70-10
The quantity of what the sample constitutes1 CAN From where was the sample collectedManufacturer
First name of sampler or witnessed byValorie Last name of sampler or witnessed byRice
Title of samplerCOC program Laboratory sample identification7010-0837
The fabricator/manufacturer/facility nameValero Benicia Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Asphalt Binder SupplierNot set MultigradeNot set
Multigrade TypeNot set JMF Verification ID
Test Details
DIME Sample ID: 2020-10-05-31
DIME Test ID: 2020-10-05-31-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2020-12-01
Test Results

Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 11/23/2020
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 176.033 grams
Mass of container #1 before test (m1i): 211.118 grams
Mass of container #1 after test (m1f): 211.005 grams
Average mass change:-0.322 percent
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs

Test was verified on 12/01/2020