Test 2020-11-16-15-2 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 214756
DEA: 050N7AU4
EFIS: 0520000030
DIST-CO-RTE-PM05-SB-101-1.4/4.8
Work DescriptionSegment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location DescriptionCARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
Sample Information
Sample Taken Date11/16/2020 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/17/2020
Sample typeQuality Control A brief description of the sampleConcrete Aggregates
The quantity of what the sample constitutes3 bags From where was the sample collectedSource
First name of sampler or witnessed byIsidro Last name of sampler or witnessed byBuenrostro
Title of samplerQC Technician Laboratory sample identification
The fabricator/manufacturer/facility nameHanson - Santa Barbra Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameOH Sign Foundation 9
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-42-0003
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedbelt cut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number63511N0P Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2020-11-16-15
DIME Test ID: 2020-11-16-15-2
Testing Lab: Sequoia Consultant
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-11-20
Test Results

What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Leo Santamaria
Date of test: 11/19/2020
Cumulative percent passing the 3/8 in. sieve:100 %
Cumulative percent passing the #4 sieve:98 %
Cumulative percent passing the #8 sieve:88 %
Cumulative percent passing the #16 sieve:76 %
Cumulative percent passing the #30 sieve:53 %
Cumulative percent passing the #50 sieve:23 %
Cumulative percent passing the #100 sieve:5 %
Cumulative percent passing the #200 sieve:2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/20/2020