Test 2020-10-28-12-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 213568
DEA: 034H6904
EFIS: 0319000026
DIST-CO-RTE-PM03-SAC-12-
Work DescriptionMajor Damage Restoration (Emergency Opening)
Location DescriptionNot set
Sample Information
Sample Taken Date10/28/2020 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/29/2020
Sample typeQuality Assurance A brief description of the sampleTrinity Lightweight
The quantity of what the sample constitutes1-5 gallon bucket From where was the sample collectedJob Site
First name of sampler or witnessed bynot available Last name of sampler or witnessed bynot available
Title of sampler Laboratory sample identification20-PCCF-0218
The fabricator/manufacturer/facility namena Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)na
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedat job site
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2020-10-28-12
DIME Test ID: 2020-10-28-12-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-11-20
Test Results

What type of gradation is being tested?: Fine Aggregate
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Measured
Tester's full name: Jay Horton
Date of test: 11/02/2020
Cumulative mass retained on the 3/8 in. sieve: 0 grams
Cumulative mass retained on the #4 sieve: 0 grams
Cumulative mass retained on the #8 sieve: 191.6 grams
Cumulative mass retained on the #16 sieve: 416.8 grams
Cumulative mass retained on the #30 sieve: 281.2 grams
Cumulative mass retained on the #50 sieve: 149.3 grams
Cumulative mass retained on the #100 sieve: 65 grams
Cumulative mass retained on the #200 sieve: 28.4 grams
Cumulative mass retained on the pan: 25.3 grams
Total mass of sample tested: 1157.6 grams
Cumulative percent passing the 3/8 in. sieve:100 %
Cumulative percent passing the #4 sieve:100 %
Cumulative percent passing the #8 sieve:83.4 %
Cumulative percent passing the #16 sieve:47.4 %
Cumulative percent passing the #30 sieve:23.2 %
Cumulative percent passing the #50 sieve:10.3 %
Cumulative percent passing the #100 sieve:4.6 %
Cumulative percent passing the #200 sieve:2.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/20/2020