Summary for Test 2020-10-28-12-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 213568 DEA: 034H6904 EFIS: 0319000026 |
---|---|
DIST-CO-RTE-PM | 03-SAC,SAC/SOL-12-0-0.4/26.3-26.4, 0.0-0.4/26.3-26.4 |
Award Date | 08/13/2018 |
Closeout Date | 08/28/2023 |
Work Description | Major Damage Restoration (Emergency Opening) |
Location Description | Not set |
QA Service Level | 1 (Verified on 08/24/2018) |
Sample Information
Sample Taken Date | 10/28/2020 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/29/2020 |
Sample type | Quality Assurance | A brief description of the sample | Trinity Lightweight |
The quantity of what the sample constitutes | 1-5 gallon bucket | From where was the sample collected | Job Site |
First name of sampler or witnessed by | not available | Last name of sampler or witnessed by | not available |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 20-PCCF-0218 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | na | Transportation Laboratory (TL) Number | na |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | na |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | at job site | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-28-12
DIME Test ID: 2020-10-28-12-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-11-20
Test Results
What type of gradation is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Jay Horton
Date of test: 11/02/2020
Cumulative Mass Retained | Cumulative Percent Passing | |||||
---|---|---|---|---|---|---|
1157.6 grams | ||||||
0.0 grams | 100 % | |||||
0.0 grams | 100 % | |||||
191.6 grams | 83.4 % | |||||
416.8 grams | 47.4 % | |||||
281.2 grams | 23.2 % | |||||
149.3 grams | 10.3 % | |||||
65.0 grams | 4.6 % | |||||
28.4 grams | 2.2 % | |||||
25.3 grams |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/20/2020 ✔