Summary for Test 2020-10-27-12-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 215314 DEA: 07333004 EFIS: 0716000298 |
---|---|
DIST-CO-RTE-PM | 07-LA-5,5-15.1/22.9 |
Award Date | 10/20/2022 |
Closeout Date | Not set |
Work Description | PROJECT PILOT 1 |
Location Description | LOS ANGELES COUNTY IN AND NEAR LOS ANGELES ON ROUTE 5 FROM 0.1 MILE SOUTH OF CALZONA STREET TO 0.1 MILE SOUTH OF RIVERSIDE DRIVE AND ROUTE 2 AT LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER |
QA Service Level | 1 (Verified on 07/12/2021) |
Sample Information
Sample Taken Date | 10/27/2020 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/16/2020 |
Sample type | Per Request | A brief description of the sample | native soil |
The quantity of what the sample constitutes | 110.74 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Mercedes | Last name of sampler or witnessed by | Merino |
Title of sampler | TEC | Telephone number of sampler | 916-208-7623 |
Laboratory sample identification | CR20200507 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | C4685705 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | 33909 | Structure unique identifier | 07-LA-5-R15.1/R22.9 |
Structure name | A-20-001 |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | A-20-001 |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Soil Corrosion | A detailed description of where the material sample was collected | 0-25 feet depth |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-10-27-12
DIME Test ID: 2020-10-27-12-1
Testing Lab: Wood
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-11-20
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Sarah Mauri
Date of test: 11/17/2020
Minimum soil resistance of the lab measurement: 2600 Ohms
Soil sample temperature: 19 C
Soil box constant: 1
pH of soil: 7.33
Minimum soil resistance corrected to 15.5: 2827.50 Ohm-cm
Minimum soil resistivity at 15.5: 2827.5 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/20/2020 ✔