Test 2020-10-29-12-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 213603
DEA: 07301504
EFIS: 0714000020
DIST-CO-RTE-PM07-LA-1,10-R34.6/35.2,R2.1/18.4
Work DescriptionREPLACING CONCRETE AND AC PAVEMENT
Location DescriptionLOS ANGELES COUNTY IN SANTA MONICA AND LOS ANGELES ON ROUTE 1 FROM 0.1 MILE WEST OF MAIN STREET OVERCROSSING TO ROUTE 1/10 SEPARATION AND ON ROUTE 10 FROM ROUTE 1/10 SEPARATION TO ROUTE 5/10 SEPARATION AND AT ROUTE 10/110 SEPARATION
Sample Information
Sample Taken Date10/29/2020 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/6/2020
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15 0.5% LAS
The quantity of what the sample constitutes4 Bags Coldfeed Agg., 2 Bags Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Irwindale Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0661A-20
The fabricator/manufacturer/facility nameVulcan Materials-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number220813A IRW LTR A detailed description of where the material sample was collectedBelt Cut at Vulcan Irwindale Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2020-10-29-12
DIME Test ID: 2020-10-29-12-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-11-17
Test Results

What type of gradation is being tested?: Combined Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Calculated
Tester's full name: Satish Jain/Larry Diaz
Date of test: 11/08/2020
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:97 %
Cumulative percent passing the 1/2 in. sieve:79 %
Cumulative percent passing the 3/8 in. sieve:67 %
Cumulative percent passing the #4 sieve:45 %
Cumulative percent passing the #8 sieve:32 %
Cumulative percent passing the #16 sieve:22 %
Cumulative percent passing the #30 sieve:15 %
Cumulative percent passing the #50 sieve:9 %
Cumulative percent passing the #100 sieve:6 %
Cumulative percent passing the #200 sieve:3.6 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation

Test was verified on 11/17/2020