Summary for Test 2020-11-09-11-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 214890
DEA: 080A4414
EFIS: 0818000047
COOP: 081894
DIST-CO-RTE-PM08-RIV-I-15-17.6/19.6
Award Date03/11/2020
Closeout DateNot set
Work DescriptionConstruction consists of additional of two new lanes on Railroad Canyon Road through interchange, reconstruction of the northbound diamond ramps to hook ramps to connect to Grape Street , construction of auxiliary and deceleration lanes on I-15
Location DescriptionLocated at City of Lake Elsinore , 1.6 Mile South to 0.4 Mile North of Railroad Canyon Road undercrossing in Riverside County, CA.
QA Service Level2 (Verified on 03/26/2020)

Sample Information

Sample Taken Date11/09/2020 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/12/2020
Sample typeQuality Assurance A brief description of the sampleCoupon Casting
The quantity of what the sample constitutes2 From where was the sample collectedDistributor
First name of sampler or witnessed byDebbie Last name of sampler or witnessed byOzuna
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDSI Farrar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)I290
Part Number (s)68 27 172 Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)Farrar Corporation
Prestressing ManufacturerDSI

Test Details

DIME Sample ID: 2020-11-09-11
DIME Test ID: 2020-11-09-11-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2020-11-13

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: fsaylor
Date of test: 11/13/2020
UTM: 67kip
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1I2900.4980.19478637171111029.5fsaylor
2I2900.4980.194786380211242110.3fsaylor

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 11/13/2020