Test 2020-04-17-18-5 (AASHTO T269-14) Summary

Project Information
Project IdentifiersProject ID: 214628
DEA: 031G6604
EFIS: 0319000116
DIST-CO-RTE-PM03-BUT-162-12.6/15.6
Work DescriptionCOLD IN-PLACE RECYCLING, RHMA-G OVERLAY, AND COLD PLANE AC PAVEMENT.
Location DescriptionBUTTE COUNTY IN AND NEAR OROVILLE FROM 0.8 MILE EAST OF WILBUR ROAD TO FEATHER RIVER BRIDGE
Sample Information
Sample Taken Date4/17/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/20/2020
Sample typeVerification A brief description of the sample1/2 inch RHMA-G
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byKenny witness not sampler Last name of sampler or witnessed byMcHugh witness not sampler
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameTeichert-Hallwood Drum Plant Transportation Laboratory (TL) NumberC779100
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number JMF Verification ID JMF3513-2020-216
Test Details
DIME Sample ID: 2020-04-17-18
DIME Test ID: 2020-04-17-18-5
Testing Lab: CT D03 - North Region Materials Lab
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2020-11-13
Test Results

Number of tests: 3
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 06/02/2020
Percent Air Voids: 5.1 %
Percent Air Voids 2: 5.2
Percent Air Voids 3: 4.9
Percent Air Voids Average:5
General comments (publicly viewable) (Max 1000 characters): JMF20-017

Test was verified on 11/13/2020