Summary for Test 2020-10-29-13-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 209520 DEA: 06470904 EFIS: 0600000973 COOP: 061529 |
---|---|
DIST-CO-RTE-PM | 06-MAD-99-R7.5/15.1 |
Award Date | 03/14/2019 |
Closeout Date | 05/11/2023 |
Work Description | WIDEN FREEWAY FROM 4 LANES TO 6 LANES. |
Location Description | MADERA COUNTY IN AND NEAR MADERA FROM AVENUE 12 OVERCROSSING TO 0.9 MILE NORTH OF AVENUE 17 OVERCROSSING |
QA Service Level | 1 (Verified on 03/16/2016) |
Sample Information
Sample Taken Date | 10/29/2020 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/10/2020 |
Sample type | Acceptance | A brief description of the sample | Asphalt Binder PG 70-10 |
The quantity of what the sample constitutes | 1 can Test #30 | From where was the sample collected | Source |
First name of sampler or witnessed by | Vulcan | Last name of sampler or witnessed by | tech |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | vulcan madera | Transportation Laboratory (TL) Number | 057045 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | Not set | |
Time of sample | Not set | HMA Supplier | Not set |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-29-13
DIME Test ID: 2020-10-29-13-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2020-12-01
Test Results
Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 11/12/2020
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 174.670 grams
Mass of container #1 before test (m1i): 208.980 grams
Mass of container #1 after test (m1f): 208.930 grams
Average mass change: -0.146 percent
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 12/1/2020 ✔