Summary for Test 2020-05-14-57-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 214422
DEA: 040J6424
EFIS: 0414000476
DIST-CO-RTE-PM04-SON-101-32.8/R54.2
Award Date12/24/2019
Closeout DateNot set
Work DescriptionCRACK, SEAT AND OVERLAY WITH RHMA AND HMA, AND REPLACE CULVERTS.
Location DescriptionSONOMA COUNTY AT VARIOUS LOCATIONS FROM LIMERICK LANE OVERCROSSING TO ROUTE 101/128 SEPARATION
QA Service Level1 (Verified on 09/23/2019)

Sample Information

Sample Taken Date05/14/2020 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/09/2020
Sample typeAcceptance A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes1 Can, #1 Test From where was the sample collectedSource
First name of sampler or witnessed byanthony Last name of sampler or witnessed byValdez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero - Benicia Transportation Laboratory (TL) Number861879
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-14-57
DIME Test ID: 2020-05-14-57-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2020-11-23

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 11/10/2020
Ductility of test #1 (D1): 75 cm
Ductility of sample: 75 cm
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs

Test was verified on 11/23/2020