Test 2020-07-01-41-5 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 214685
DEA: 024E46U4
EFIS: 0216000122
DIST-CO-RTE-PM02-LAS-36-6.0/14.6
Work DescriptionREPLACE BRIDGE, ROADWAY EXCAVATION, HMA, CLASS 2 AB AND DRAINAGE WORK.
Location DescriptionLASSEN COUNTY NEAR WESTWOOD FROM 1.3 MILES WEST OF GOODRICH CREEK BRIDGE TO 1.0 MILE WEST OF WILLARD CREEK ROAD
Sample Information
Sample Taken Date7/1/2020 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/2/2020
Sample typeVerification A brief description of the sampleCombined Untreated Virgin 3/4-inch Type A Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byJoe Last name of sampler or witnessed byDelgado
Title of sampler Laboratory sample identificationD78503F
The fabricator/manufacturer/facility nameWard Lake Pit Transportation Laboratory (TL) Number896803
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-18-0008
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedLab-Batched from Sized Untreated Aggregate Stockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 20-08-S2 Lot numberUnknown
Sublot numberUnknown JMF Verification ID JMF3513-2020-212
Test Details
DIME Sample ID: 2020-07-01-41
DIME Test ID: 2020-07-01-41-5
Testing Lab: CT D02 - North Region Materials Lab
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-11-16
Test Results

Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 11/05/2020
Mass of saturated surface dry sample (before pycnometer) (S): 499.5 grams
Mass of the pycnometer with water and aggregate (C): 961.5 grams
Mass of the pycnometer with water (B): 649 grams
Mass of the oven dried sample (before pycnometer) (A): 487.5 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 499.5 grams
Mass of the oven dry aggregate (for absorption) (A): 487.5 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.607
Bulk specific gravity (SSD Basis):2.671
Apparent specific gravity:2.786
Absorption:2.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/16/2020