Summary for Test 2015-01-29-5-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 210188 DEA: 656A27520 EFIS: 0000001176 |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Type 50C Median Barrier Test Section |
Location Description | CHP Academy - RSRG Dynamic Test Facility |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/29/2015 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/26/2015 |
Sample type | Quality Control | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | She | Last name of sampler or witnessed by | Vang |
Title of sampler | TET | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CHP Academy | Transportation Laboratory (TL) Number | 82778 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | RP075NR5W |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | na |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | CHP Academy | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-01-29-5
DIME Test ID: 2015-01-29-5-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-03-05
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mullins
Date of test: 03/05/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.03 in
Average diameter of cylinder 2: 6.03 in
Maximum load on cylinder 1: 160808 lb
Maximum load on cylinder 2: 163250 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 35 days
Cross sectional area of cylinder 1: 28.56 in^2
Cross sectional area of cylinder 2: 28.56 in^2
Compressive strength of cylinder 1: 5630.5 psi
Compressive strength of cylinder 2: 5716.0 psi
Compressive strength (to nearest 10 psi): 5670 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 3/5/2015 ✔