Summary for Test 2020-09-24-17-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214601
DEA: 041J5694
EFIS: 0419000313
DIST-CO-RTE-PM04-SM-101-0.0/21.8
Award Date12/03/2019
Closeout Date09/28/2022
Work DescriptionSan Mateo US 101 Express Lanes North
Location DescriptionNot set
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date09/24/2020 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/27/2020
Sample typeQuality Assurance A brief description of the sampleHRC 500 510 Couplers
The quantity of what the sample constitutes200 From where was the sample collectedJob Site
First name of sampler or witnessed byShady Last name of sampler or witnessed byBesada
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePacific Steel Group Transportation Laboratory (TL) NumberC613892
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelHRC 500 / 510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A193741 351818 Rebar Heat Number(s)3500010655
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2020-09-24-17
DIME Test ID: 2020-09-24-17-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-10-27

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/27/2020
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 8/25mm1-0.010.797857799465OK Neckingspaine

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 10/27/2020