Summary for Test 2020-10-09-25-1

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 214685
DEA: 024E46U4
EFIS: 0216000122
DIST-CO-RTE-PM02-LAS-36-6.0/14.6
Award Date05/08/2020
Closeout Date08/14/2023
Work DescriptionREPLACE BRIDGE, ROADWAY EXCAVATION, HMA, CLASS 2 AB AND DRAINAGE WORK.
Location DescriptionLASSEN COUNTY NEAR WESTWOOD FROM 1.3 MILES WEST OF GOODRICH CREEK BRIDGE TO 1.0 MILE WEST OF WILLARD CREEK ROAD
QA Service Level1 (Verified on 03/02/2020)

Sample Information

Sample Taken Date10/09/2020 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/23/2020
Sample typeAcceptance A brief description of the sampleAsphalt Binder PG 58-34M
The quantity of what the sample constitutes#15 Test, NO Test #14(897039) From where was the sample collectedSource
First name of sampler or witnessed byCGI Last name of sampler or witnessed byCGI
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMarathon Transportation Laboratory (TL) Number897040
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-10-09-25
DIME Test ID: 2020-10-09-25-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2020-10-28

Test Results


Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 10/26/2020
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 177.692 grams
Mass of container #1 before test (m1i): 213.179 grams
Mass of container #1 after test (m1f): 213.002 grams
Average mass change: -0.499 percent
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs

Test was verified on 10/28/2020