Test 2020-10-19-1-1 (ASTM A934-13) Summary

Project Information
Project IdentifiersProject ID: 208973
DEA: 120H1004
EFIS: 1200000180
COOP: 120670
DIST-CO-RTE-PM12-ORA-405,73,405,605-9.3/24.3
Work Description(Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location DescriptionOrange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
Sample Information
Sample Taken Date10/19/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/22/2020
Sample typeQuality Assurance A brief description of the sample#7 ASTM A615 Gr. 75 Epoxy coated A934 bar
The quantity of what the sample constitutes2 From where was the sample collectedSource
First name of sampler or witnessed byCarolina Last name of sampler or witnessed byBurgan
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameWilliams Form Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL073-001-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade615
Threaded Bar TypePlain Rebar Size#7
Nut Specification for Threaded BarA615 System ManufacturerWilliams FOrm
Epoxy Coating ColorPurple Threaded Bar ApplicationSoil Nail
Coating StandardsASTM A934 epoxy Bar Heat Number(s)100102558
Nut Heat Number(s)NO NUTS Bar Lot Number
Nut Lot NumberNO NUTS Coupler Heat Number(s)
Coupler Grade
Test Details
DIME Sample ID: 2020-10-19-1
DIME Test ID: 2020-10-19-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2020-10-23
Test Results

Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 10/23/2020
Lower spec. limit LSL: 10
Upper spec. limit USL: 15
Bar # for First Bar: 1
Bar # for Second Bar: 2
First Bar Side 1 mean value: 13.29
First Bar Side 2 mean value: 13.63
Second Bar Side 1 mean value: 12.22
Second Bar Side 2 mean value: 12.22
First Bar Mean:13.46
Second Bar Mean:12.22
Total mean value:12.84
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/23/2020