Test 2020-10-20-5-3 (ASTM D624-00-re12) Summary

Project Information
Project IdentifiersProject ID: 214847
DEA: 074W8204
EFIS: 0720000009
DIST-CO-RTE-PM07-VEN-101-17.7
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGE AND PLACE CONCRETE BARRIER.
Location DescriptionVENTURA COUNTY IN CAMARILLO AT CENTRAL AVENUE OVERCROSSING
Sample Information
Sample Taken Date10/20/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/22/2020
Sample typeQuality Assurance A brief description of the samplebearing pad
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byBrad Last name of sampler or witnessed byStreeter
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameScougal Rubber Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)19214-1
Material/Compound/Elastomer IDna Samples Representing3
Description (size)1"x9"x19" Comments
Description (Number of Shims)na Type of Bearing PadPlain
Description (Thickness of Shims)NA Manufacturer(s)Scougal Rubber
Batch Numberna
Test Details
DIME Sample ID: 2020-10-20-5
DIME Test ID: 2020-10-20-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2020-10-29
Test Results

Number of specimens tested: 3
Input Type: Measured
Tester's full name: spaine
Date of test: 10/23/2020
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.081
Sample 1 Tear Strength: 229.4
Sample 2 Median Thickness: 0.076
Sample 2 Tear Strength: 240.7
Sample 3 Median Thickness: 0.081
Sample 3 Tear Strength: 232.9
UTM:2kip
Median of the Tear Strength Values:232.9 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Sample 2

Source: Bluehill Data Point File
Test graph for Sample 3

Source: Bluehill Data Point File
Test graph for Sample 1

Test was verified on 10/29/2020