Test 2020-10-16-1-4 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 213306
DEA: 07303404
EFIS: 0714000006
DIST-CO-RTE-PM07-VEN-33-0.0/6.3
Work DescriptionCOLD PLANE AC PVMT, PLACE RUBBERIZED AC (TYPE G), AND REPLACE PCC PVMT
Location DescriptionVENTURA COUNTY IN AND NEAR VENTURA FROM ROUTE 33/101 SEPARATION TO 0.1 MILE SOUTH OF PARK VIEW DRIVE
Sample Information
Sample Taken Date10/16/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/17/2020
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15
The quantity of what the sample constitutes5 Bags Of Agg., 1 Bag Of Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byMD Last name of sampler or witnessed byShajahan
Title of sampler Laboratory sample identification0612A-20
The fabricator/manufacturer/facility nameVulcan Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number220831 SVA MPC A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2020-10-16-1
DIME Test ID: 2020-10-16-1-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-10-26
Test Results

Input Type: Measured
Tester's full name: Michael Magana
Date of test: 10/20/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 968.2 grams
Mass of the pycnometer with water (B): 655.8 grams
Mass of the oven dried sample (before pycnometer) (A): 491.3 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491.3 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.619
Bulk specific gravity (SSD Basis):2.665
Apparent specific gravity:2.746
Absorption:1.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/26/2020