Summary for Test 2020-07-30-16-3

Test performed: ASTM D2369-Jul10

Project Information

Project IdentifiersProject ID: 214946
DEA: 060X1504
EFIS: 0618000233
DIST-CO-RTE-PM06-FRE-99-0.9/30.5
Award Date06/12/2020
Closeout Date01/26/2021
Work DescriptionPOLYESTER CONCRETE OVERLAY.
Location DescriptionFRESNO COUNTY FROM CONEJO AVENUE UNDERCROSSING TO GRANTLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 05/21/2020)

Sample Information

Sample Taken Date07/30/2020 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/30/2020
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byTikusis
Title of samplerTechnical Director Telephone number of sampler7073309227
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypePolyester Mfg. Lot Number(s)1267926
Batch number1267926 Mix number1267926

Test Details

DIME Sample ID: 2020-07-30-16
DIME Test ID: 2020-07-30-16-3
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Test Release Date: 2020-10-19

Test Results


Input Type: Calculated
Tester's full name: Larry McCrum
Date of test: 10/19/2020
Mean of two volatile content determination: 46.5
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/19/2020