Summary for Test 2020-10-12-35-2

Test performed: ASTM D92-12b

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/12/2020 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/12/2020
Sample typeQuality Control A brief description of the sampleAsphalt Modifier - Trico Refining - 2.5%
The quantity of what the sample constitutes1 From where was the sample collectedSource
First name of sampler or witnessed byMike Last name of sampler or witnessed byPaulson
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials - Pleasanton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Modifier Asphalt Modifier TypeTricor Refining
Asphalt Modifier Mix NumberNot set

Test Details

DIME Sample ID: 2020-10-12-35
DIME Test ID: 2020-10-12-35-2
Testing Lab: Vulcan Materials Company - Pleasanton
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Test Release Date: 2020-10-16

Test Results


Unit system used?: US Units
Ambient Barometric Pressure unit?: kPa
Input Type: Calculated
Tester's full name: Mike Paulson
Date of test: 10/12/2020
Corrected Flash Point: 435 F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/16/2020