Test 2020-09-30-3-9 (ASTM F606-14) Summary

Project Information
Project IdentifiersProject ID: 214393
DEA: 101C6204
EFIS: 1015000001
DIST-CO-RTE-PM10-SJ,MPA,MER,SBT,SJ,SCL-5,88,99,104,120,etc.-15.69/29.56
Work DescriptionMODIFY ELECTRICAL SYSTEMS, INSTALL CAMERA SYSTEMS AND PLACE HMA.
Location DescriptionAMADOR, MARIPOSA, MERCED, SAN BENITO, SAN JOAQUIN, AND SANTA CLARA COUNTIES AT VARIOUS LOCATIONS
Sample Information
Sample Taken Date9/30/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/30/2020
Sample typeQuality Assurance A brief description of the sampleAnchor Bolt Hardware 1"x 16.5"
The quantity of what the sample constitutes95 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Laboratory sample identification
The fabricator/manufacturer/facility nameUniversal Industrial Sales Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-023-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3093335 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationF1554 gr 105
Bolt Length(s)16 1/2" Nut Specificationna
Washer Specificationna FinishHGD
Diameter/Size1.0" Bolt Mfg. Lot Number96433
Rocap Test Requirement(s)na Lubricant Requirements(s)na
Test Details
DIME Sample ID: 2020-09-30-3
DIME Test ID: 2020-09-30-3-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-10-12
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/09/2020
UTM:400kip
Temperature:72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11CUNC 1 0.6069385841715488114553288192F1554 Gr 105 Headed Bolt

General comments (publicly viewable) (Max 250 characters): F1554 Gr 105 Headed Bolt
Test Graph
Source: Bluehill Data Point File

Test was verified on 10/12/2020