Summary for Test 2020-09-29-11-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 215113 DEA: 021J2404 EFIS: 0220000048 |
---|---|
DIST-CO-RTE-PM | 02-SHA,VAR-273,Var-Var |
Award Date | 12/02/2019 |
Closeout Date | 05/23/2022 |
Work Description | PSPS Streetlight Backing plates-Steel Cantilever structure for solar panels |
Location Description | Not set |
QA Service Level | 1 (Verified on 08/17/2020) |
Sample Information
Sample Taken Date | 09/29/2020 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/02/2020 |
Sample type | Quality Assurance | A brief description of the sample | 3/4"X8 domestic HDG ASTM F1554 hex head bolts with 4" threads. |
The quantity of what the sample constitutes | 16 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Roland | Last name of sampler or witnessed by | Maynard |
Title of sampler | QA Inspector | Telephone number of sampler | (51) 774-1269 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S64-006-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 1202021930 | Nut Mfg. Lot Number(s) | NA |
Washer Mfg. Lot Number(s) | NA | Bolt Specification | ASTM F1554 |
Bolt Length(s) | 8 | Nut Specification | NA |
Washer Specification | NA | Finish | HDG |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 120202193061 |
Rocap Test Requirement(s) | Lubricant Requirements(s) | NA |
Test Details
DIME Sample ID: 2020-09-29-11
DIME Test ID: 2020-09-29-11-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-10-08
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/07/2020
UTM: 400kip
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | UNC 3/4 | 0.334 | 25036 | 111 | 74943 | 52242 | 17449 | F1554 Headed Bolt |
General comments (publicly viewable) (Max 1000 characters): F1554 Headed Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 10/8/2020 ✔